Ing. Pavel Štajnrt
Construction Expert Witness
Court-Appointed Expert • Construction

Building assessments
and expert opinions
you can
rely on.

I specialise in building envelope failures, thermal imaging diagnostics, airtightness, and daylight & sunlight assessment under Czech standards.

15+years of expert practice
200+reports & assessments
DEKPROJEKTexpert office
Envelope, roof and façade assessments Building envelope diagnostics
Envelope, roof and façade assessments Defects, thermography, airtightness
Case Studies

Selected projects from practice

Anonymised assessments with real outcomes. Click any card to read the diagnosis and conclusion.

[ Foto reference ] Building defects
Apartment building • Prague 6 • 2024

Cracks in external wall after thermal insulation

A year after polystyrene insulation, diagonal cracks appeared at window corners. Thermography and probes revealed insufficient anchoring and missing dilatation joints.

Read case →
[ Foto reference ] Thermography
Family house • Central Bohemia • 2024

Roof insulation defect claim

The investor claimed unexpectedly high heating costs in a new build. Thermography revealed systematic thermal bridges at the roof-to-wall connection.

Read case →
[ Foto reference ] Airtightness
Passive house • Brno • 2023

Failed n50 0.6 target on a passive house

A control Blower Door measurement revealed n50 = 1.4 vs. the design value 0.6. I identified 7 critical leak points; after repairs the building reached n50 = 0.55.

Read case →
[ Foto reference ] Daylight
Neighbour dispute • Pilsen • 2024

Daylight loss caused by neighbouring construction

Daylight factor assessment in an existing flat after construction of an adjacent building. The report demonstrated a drop below the limit required by ČSN 73 0580.

Read case →
[ Foto reference ] Building defects
Commercial building • Ostrava • 2023

Recurring basement moisture

Diagnosis of recurring basement moisture despite repeated waterproofing repairs. Probes revealed a combination of pressurised water and faulty drainage.

Read case →
[ Foto reference ] Thermography
Office building • Prague • 2024

Flat roof leak detection by thermography

Thermographic survey located the leak point without extensive probing. The investor saved 80 % of the cost compared to a full re-roofing.

Read case →
[ Portrétní fotka
Pavla Štajnrta ]
Court-appointed
expert construction
About

Pavel Štajnrt, Eng.

I am a court-appointed expert witness in construction, specialising in building defects and building physics. I work within the expert office DEKPROJEKT s.r.o., a registered expert institution.

I have spent over 15 years assessing buildings — from family houses to apartment blocks and commercial properties. I combine knowledge of building structures with measurement methods: thermal imaging, Blower Door testing and lighting simulation software.

I prepare reports for courts, insurance companies, investors and private clients. My priorities are technical precision, clear reasoning and defensible conclusions.

Expert Witness Construction, appointed by Regional Court
ČKAIT Chartered Engineer (CZ)
Thermography Level 1 / 2 certified
Blower Door Certified operator

Download CV (PDF)

Frequently Asked Questions

What clients ask before commissioning a report

What's the difference between an expert report and a technical opinion? +

An expert report is a formal document prepared by a court-appointed expert or expert institute under Act No. 254/2019 Coll. It can be used as evidence in court. A technical opinion is an analysis without an expert seal — sufficient for the investor's own decisions or for warranty claims.

How much does an expert report cost? +

The price depends on scope — number of measurements, complexity of the building and depth of analysis. After an initial consultation and site visit I send a fixed-price quote. Reports for family houses usually range in the tens of thousands of CZK; court and commercial reports tend to be higher.

How long does it take to prepare a report? +

Standard turnaround is 4–6 weeks from the site visit. In urgent cases (failures, upcoming hearings) we can shorten it by agreement. Thermography and Blower Door measurements take roughly one day; the rest is analysis and writing.

When do I need thermography and when a Blower Door test? +

Thermography shows where heat escapes — thermal bridges, insulation defects, water ingress. The Blower Door test measures how much air leaks through the envelope per hour. The two methods are often combined: Blower Door confirms there is a problem; thermography during the test pinpoints the exact spot.

Do you also assess neighbour disputes about sunlight access? +

Yes. I prepare assessments per ČSN 73 0581 and 73 0580 for both the affected party and the planning investor. The output includes calculated sunlight duration and daylight factor with graphical evidence.

Contact

Let's discuss your case

Fill in the form or reach out directly. The first consultation is usually by phone and non-binding.

  • Phone +420 XXX XXX XXX (DEKPROJEKT office)
  • Coverage Czech Republic, based in Prague
  • Response time Usually within 24 hours

By submitting you agree to your data being processed for inquiry handling.